| Electrical Specifications | ||||
| AC Current via Jaw | ||||
| Range | 374 and 375 376 | 600.0 A 999.9 A | ||
| Resolution | 0.1 A | |||
| Accuracy | 2% ?? 5 digits (10-100 Hz) 2.5% ?? 5 digits (100-500 Hz) | |||
| Crest Factor (50/60 Hz) | 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2% for C.F. > 2 | |||
| AC Current via Flexible Current Probe | ||||
| Range | 2500 A | |||
| Resolution | 374 and 375 | 0.1 A (?? 600 A) 1 A (?? 2500 A) | ||
| 376 | 0.1 A (?? 999.9 A) 1 A (?? 2500 A) | |||
| Accuracy | 3% ??5 digits (5 ?C 500 Hz) | |||
| Crest Factor (50/60Hz) | 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 | |||
| DC Current | ||||
| Range | 374 and 375 376 | 600.0 A 999.9 A | ||
| Resolution | 0.1 A | |||
| Accuracy | 2% ?? 5 digits | |||
| AC Voltage | ||||
| Range | 374 and 375 376 | 600.0 V 1000 V | ||
| Resolution | 374 and 375 376 | 0.1 V 0.1 V (?? 600.0 V) 1 V (?? 1000 V) | ||
| Accuracy | 1.5% ?? 5 digits (20 ?C 500 Hz) | |||
| DC Voltage | ||||
| Range | 374 and 375 376 | 600.0 V 1000 V | ||
| Resolution | 374 and 375 376 | 0.1 V 0.1 V (?? 600.0 V) 1 V (?? 1000 V) | ||
| Accuracy | 1% ?? 5 digits | |||
| mV dc | ||||
| Range | 375 and 376 | 500.0 mV | ||
| Resolution | 0.1 mV | |||
| Accuracy | 1% ?? 5 digits | |||
| Frequency via Jaw | ||||
| Range | 375 and 376 | 5.0 – 500.0 Hz | ||
| Resolution | 0.1 Hz | |||
| Accuracy | 0.5% ?? 5 digits | |||
| Trigger Level | 5 ?C 10 Hz, ??10 A | |||
| 10 ?C 100 Hz, ??5 A | ||||
| 100 ?C 500 Hz, ??10 A | ||||
| Frequency via Flexible Current Probe | ||||
| Range | 375 and 376 | 5.0 – 500.0 Hz | ||
| Resolution | 0.1 Hz | |||
| Accuracy | 0.5% ?? 5 digits | |||
| Trigger Level | 5 ?C 20 Hz, ?? 25 A | |||
| 20 ?C 100 Hz, ?? 20 A | ||||
| 100 ?C 500 Hz, ?? 25 A | ||||
| Resistance | ||||
| Range | 374 375 and 376 | 6000 ?? 60 k?? | ||
| Resolution | 374 | 0.1 ?? (?? 600 ??) 1 ?? (?? 6000 ??) | ||
| 375 and 376 | 0.1 ?? (?? 600 ??) 1 ?? (?? 6000 ??) 10 ?? (?? 60 k??) | |||
| Accuracy | 1% ?? 5 digits | |||
| Capacitance | ||||
| Range | 1000 ??F | |||
| Resolution | 0.1 ??F (?? 100 ??F) 1 ?? F (?? 1000 ??F) | |||
| Accuracy | 1% ?? 4 digits | |||
| Mechanical Specifications | ||||
| Size (L x W x H) | 246 mm x 83 m x 43 mm | |||
| Weight | 388 g | |||
| Jaw Opening | 34 mm | |||
| Flexible Current Probe Diameter | 7.5 mm | |||
| Flexible Current Probe Cable Length (head to electronics connector) | 1.8 m | |||
| Environmental Specifications | ||||
| Operating Temperature | 10??C ?C +50??C | |||
| Storage Temp | -40??C ?C +60??C | |||
| Operating Humidity | Non condensing (< 10 ?C??C) ?? 90% RH (at 10??C ?C 30??C) ?? 75% RH (at 30??C ?C 40??C) ?? 45% RH (at 40??C ?C 50??C) | |||
| Operating Altitude | 3000 meters | |||
| Storage Altitude | 12,000 meters | |||
| EMC | EN 61326-1:2006 | |||
| Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28??C or below 18??C | |||
| Safety Specifications | ||||
| Safety Compliance | CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 | |||
| Agency Approvals | ||||
| Batteries | 2 AA, NEDA 15A, IEC LR6 | |||
Send Inquiry